180-230mm – Single story – 4.5m

R12,504

With this ‘Standard Single Story Flue Kit of 4.5m’, your fireplace is required to be installed with the flue exiting straight up above the fireplace, and out through the ceiling and the roof.  Should you require a flue installation other than this installation scenario e.g. via an external wall and up the outside wall towards the roof, then let us know and we will quote you accordingly.

A good flue kit consists of both insulated and plain flue ducts, which is the industry standard. The flue piece which connects the plain flue duct with the insulated flue duct is called an insulated “end-cap”, and this item of the flue kit is installed about 300mm below ceiling level and runs into the roof space. Single skin ducts get really hot and serve as an extension of the fireplace by helping to heat your interior. Whereas an insulated duct is composed of two plain flue ducts within each other, with an insulation material between them and has a large diameter than a plain duct. An insulated duct only gets warm and this is much safer. In this way, your waterproofing will be more durable as well, as the outside of the insulated flue duct will not expand and contract upon heating and cooling down like a single skin flue duct does. Lastly, an insulated duct will vastly decrease the build-up of condensation within your flue, as the insulation prevents the hot smoke from cooling down too quickly. It is therefore preferable and safer to use insulated flues once the flue duct leaves the interior of the room that is being heated.

All our flue kits include the European CE certified Atritube flue system which is imported from Greece. All Atritube flues are made from superior 0.4mm thickness, 304-grade Stainless Steel, which is suitable to withstand long-term corrosion from the harsh chemicals within the flue gases of closed combustion fireplaces. These flues are seam welded and utilize a clamping method of assembly which makes drilling and pop riveting obsolete. All stainless steel flues discolour overtime, due to a natural chemical reaction caused by exposure to 02 in the air and the heat from your fireplace. This creates ‘living art’ in your home, as the colours range from golden to amber, even purples and blues, depending on how hot your fireplace is fired.  If you’d prefer something other than a ‘stainless steel look’, then you can choose to have your flues sprayed in the same colour as your fireplace i.e. black, anthracite grey, Ivory. This is done at an additional charge and needs to be pre-ordered with your fireplace.

Installation Type

Straight up through the ceiling and roof

Total Height of Flue

7m (Standard Double Story Installation)

Flue Width

180/230 mm

Thickness

0.4 mm

Material

1m Duct

Flue Width

80 mm, 100 mm, 130 mm, 150 mm, 180 mm, 200 mm, 230 mm, 250 mm, 300 mm, 350 mm, 400 mm, 450 mm

0.5m Duct

Flue Width

80 mm, 100 mm, 130 mm, 150 mm, 180 mm, 200 mm, 230 mm, 250 mm, 400 mm

1m Insulated Endcap

Flue Width

80/130 mm, 130/180 mm, 150/200 mm, 180/230 mm, 200/250 mm, 100/150 mm, 250/300 mm

1m Insulated Duct

Flue Width

80/130 mm, 130/180 mm, 150/200 mm, 180/230 mm, 200/250 mm, 100/150 mm, 250/300 mm

Ceiling plate

Flue Width

100mm, 80 mm, 130 mm, 150 mm, 180 mm, 200 mm, 230 mm, 250 mm, 300 mm

Clamp

Flue Width

80 mm, 100 mm, 130 mm, 150 mm, 180 mm, 200 mm, 230 mm, 250 mm, 300 mm, 400 mm

Clamp

Flue Width

80 mm, 100 mm, 130 mm, 150 mm, 180 mm, 200 mm, 230 mm, 250 mm, 300 mm, 400 mm

Storm Collars

Material

Size

80mm Storm Collar, 130mm Storm Collar, 150mm Storm Collar, 180mm Storm Collar, 200mm Storm Collar, 230mm Storm Collar, 250mm Storm Collar

Bell Cowl Female

Flue Width

130 mm, 150 mm, 180 mm, 200 mm, 230 mm, 250 mm, 300 mm

1m Duct

180 mm

0.5m Duct

180 mm

1m Insulated Endcap

180/230 mm

1m Insulated Duct × 2

180/230 mm

Ceiling plate

230 mm

Clamp × 2

180 mm

Clamp × 3

230 mm

EPDM #4 Sloped Roof Flashing 150-230mm Base: 600mm*705mm

R588

Storm Collars

230mm Storm Collar

Bell Cowl Female

230 mm